6
INCREASED THERMODYNAMIC
EFFICIENTIES
gForce’s design incorporates rifl ed tubing cool-
ing coils. Rifl e tubing is similar to borings in a
gun barrel which forces the bullet to rotate. In a
cooling coil the rifl ings force the refrigerant gas
and liquid to rotate as it passes through the coil.
This action forces the heavier matter, the liq-
uid and coldest refrigerant, to the outside of the
tube where the heat transfer occurs. As a result
the coldest refrigerant is in contact with warm-
est surface resulting in better heat transfer.
IMPROVED AIRFLOW DESIGN
gForce is the greatest internal capacity of an
unit manufactured by Data Aire. The increased
capacity of the gForce internal cabinet allows
for less restrictive airfl ow. When additional op-
tions are added to smaller cabinets, the static
pressure within the unit increases, making air-
fl ow more diffi cult. This is not an issue with
the gForce, as the advanced design of the big-
ger interior and the product’s quality construc-
tion ensures the highest level of effi ciency in a
precision air system
ENVIRONMENTALLY RESPONSIBLE
Data Aire offers the gForce line in either R-407C
or R-410A refrigerants. Either of these refrig-
erants comply with the requirements of the
Montreal Protocol which called for the phase
out of refrigerants that deplete the ozone layer.
R-407C is a blend of three refrigerants and has
characteristics similar to R-22. R-410A is a blend
of two refrigerants and has a higher volumetric
cooling capacity but operates at higher pressures
than either R-22 or R-407C. The choice of the
environmentally friendly refrigerant is yours.
ENERGY EFFICIENT COILS
gForce energy effi cient coils are another unique
feature engineered by Data Aire. These coils
feature rifl e tubing, a creative element that sig-
nifi cantly adds to energy effi ciency. Very simi-
lar to the borings on a rifl e that spin the bullet as
it exts the barrel, the refrigerant in a gForce unit
spins as it travels through the coil. This spinning
forces the liquid, and coldest refrigerant to the
outside surface of the coil, resulting in a higher
heat transfer and therefore higher effi ciency.
DATA AIRE DELIVERS
Standard lead time for a standard unit is 30 days
from date of order. With an optional premium
“quick ship” units can be expedited to ship in
as little as one week. All units are built to your
specifi c order and specifi cation. Not only does
Data Aire deliver standard products in short lead
times they are willing to modify designs to meet
your specifi c requirements. Call your nearest
Data Aire representative for more.