3
Table of Contents
1.0 INSTALLATION .................................................................................................. 6
1.1 Room Considerations ............................................................................................ 6
1.2 Inspection .............................................................................................................. 6
1.3 Rigging .................................................................................................................. 6
1.4 Locating the Unit ................................................................................................... 7
1.4.1 Down ow Units...................................................................................................... 7
1.4.2 Up ow Units .......................................................................................................... 8
1.5 Paperwork ............................................................................................................. 8
1.6 Storage .................................................................................................................. 8
1.7 Model Identi cation ............................................................................................... 9
2.0 PIPING .............................................................................................................. 10
2.1 Split Air Cooled Unit Piping ................................................................................. 10
2.1.1 Discharge Lines................................................................................................... 10
2.1.2 Liquid Lines ......................................................................................................... 10
2.1.3 Suction Lines.........................................................................................................11
2.1.4 Connection Sizes, Air Cooled Units......................................................................11
2.1.5 Field Piping, Remote Condenser .........................................................................11
2.1.6 Field Piping, Remote Condensing Unit ............................................................... 12
2.2 Water/Glycol Cooled Unit Piping ......................................................................... 12
2.2.1 Field Piping, Glycol System ................................................................................. 13
2.2.2 Connection Sizes, Water/Glycol Cooled Units ..................................................... 13
2.2.3 Connection Sizes, Fluid Coolers .......................................................................... 13
2.3 Auxiliary Chilled Water Coil Piping ...................................................................... 14
2.4 Condensate Drain Piping .................................................................................... 14
2.5 Humidi er Piping ................................................................................................. 15
2.5.1 Steam Generator Humidi er ................................................................................ 14
2.5.2 Dry Steam Humidi er ........................................................................................... 15
2.6 Leak Testing ........................................................................................................ 15
2.7 Evacuation........................................................................................................... 15
3.0 ELECTRICAL CONNECTIONS ........................................................................ 16
3.1 Electrical Service. . .............................................................................................. 16
3.2 Nameplate Ratings .............................................................................................. 16
3.3 Grounding............................................................................................................ 16
3.4 Voltage Tolerance ................................................................................................ 16
3.5 Auxiliary Control Wiring ....................................................................................... 16
3.6 Remote Shutdown ............................................................................................... 16
3.7 Remote Alarm Contacts ...................................................................................... 17
3.8 Remote Sensors.................................................................................................. 17
3.9 Condensate Pumps ............................................................................................. 17
3.10 Condensate Probe .............................................................................................. 17
3.11 Water Sensing Cable .......................................................................................... 17